Electric connector is a very important
electronic component for connection, plating on the connectors is also
necessary for protection and anti-corrosion, which can also improve connector
durability and wearability.
Below is plating common problems and solutions.
1.
Plating layer roughness;
Solution is to dilute the plating bath and
adjust other composition.
(2)
Temperature is high.
Solution is to lower temperature.
(3)
Cathodic current density is too
high.
(4)
Free ammonia is less.
Solution is to add ammonia.
2.
Plating darkens.
(1)
Main salt level is low.
Solution is to add main salt.
(2)
Ammonium chloride is too high.
Solution is to add main salt or raise the
temperature.
(3)
Temperature is too low.
Solution is to raise the temperature.
3.
Plating is too fragile and
connection performance is not good.
(1)
Cathodic current density is too
high.
Solution is to reduce current density.
(2)
Pretreatment is not good.
Solution is to improve pretreatment.
(3)
Cu impurity is too much.
Solution is to recover palladium and use
new plating bath.
More connector information, please visit website:http://www.sunkye.com